|
Safety switches with separate actuactor
|
 
|
For heavy duty, FD-FP-FL-FC series
- Metal or polymeric housing
- From one to three cable entries
- Protection degree: IP67
Catalog page
|
 
|
For normal duty, FR-FX-FK series
- Polymeric housing
- From one to two cable entries
- Protection degree: IP67
Catalog page
|

|
For normal duty, FW series
- Polymer housing, three M20 or M16 knock out conduit entries
- Protection degree IP67
- Cylindrical or slotted fixing holes
Catalog page
|
|
Magnetic sensors
|

|
Coded magnetic sensors
- Long life, no mechanical wear
- Stainless steel fi xing plates
- Output contacts: 2NC, 1NO+2NC or 1NO+1NC
- Insensitive to dirt
- Protection degree IP67 and IP69K
- Coded actuator
- Polymer housing
- Versions with M8 or M12 integrated connector
Catalog page
|
|
Hinge operating safety switches
|

|
Hinge switches HP series
- Metal housing, cable output from top, bottom or back
- 4 integrated cable types available
- Versions with M12 connector
- Protection degree IP67 and IP69K
- 9 contact blocks with positive opening
- Complementary hinges without contacts
Catalog page
|
 
|
Hinge operating, heavy duty FD-FL-FC series
- Metal housing
- From one to three cable entries
- Protection degree IP67
Catalog page
|
 
|
Hinge operating, normal duty FR-FM-FX-FZ-FK series
- Metal or polymeric housing
- From one to two cable entries
- Protection degree IP67
Catalog page
|
 
|
With slotted hole lever, normal duty FR-FM-FX-FZ-FK series
- Metal or polymeric housing
- From one to two cable entries
- Protection degree IP67
Catalog page
|
|
Safety switches with separate actuactor with block
|
 
|
With solenoid, very heavy duty FG series
- Actuator hold ing force 2500 N
- 8 contact blocks with 4 poles
- Metal housing, three conduit entries M20
- Protection degree IP67
- Rotating head
- Working with energized or de-energized solenoid
- Version with lock release device and emergency release push button or both
Catalog page
|
 
|
With solenoid, heavy duty FS series
- Polymeric housing
- Three cable entries
- Indipendently orientable head with two key entries
Catalog page
|
 
|
With manual mechanical duty, heavy duty FD-FP series
- Metal or polymeric housing
- From one to two cable entries
- Indipendently orientable head with two key entries
Catalog page
|
 
|
With lock, heavy duty FD-FP series
- Metal or polymeric housing
- From one to two cable entries
- Indipendently orientable head with two key entries
Catalog page
|
|
Safety handles
|

|
Safety handles P-KUBE line
- Metal housing
- Optional Lock-out device
- Compatible with safety switch FD series with separate actuator and safety switch FG series with solenoid.
Catalog page
|

|
Safety handles VF AP-S
- Light, compact and cheap
- Mechanical stop whose function is to avoid possible impacts between actuator and switch
- Optional lever for emergency opening from inside
- Compatible with safety switch FD series with separate actuator and safety switch FG series with solenoid.
Documentation
|
|
Rope safety switches
|
 
|
With reset, heavy duty FD-FP-FL-FC series
- Metal or polymeric housing
- From one to three cable entries
- Protection degree IP67
Catalog page
|
  
|
Without reset, heavy duty FD-FP-FL-FC series
- Metal or polymeric housing
- From one to three cable entries
- Protection degree IP67
Catalog page
|

|
Accessories for rope safety switches
- Items available in stock
- Compatibility with all rope safety switches
- New accessories FAST line
Catalog page
|
|
Emergency push button
|

|
Boxes with emergency stop push button CC series
- Polymeric housing
- Protection degree : from IP65
- Complete with emergency stop mushroom-head push button
Catalog page
|
|
Safety modules
|

|
Safety module CS AR for emergency stop and gate monitoring
- Single or dual channel input circuit, 24 VAC/DC; 120 VAC; 230 VAC power supply
- SIL level up to SIL 3 according to EN IEC 62061, Performance Level (PL) up to PL e according to EN ISO 13849-1and safety category up to category 4 according to EN 954-1
- Automatic, monitored or manual start versions
- Versions with inputs proper to control electromechanical contacts, electrosensible devices with PNP output, safety magnetic sensor and safety mats and bumpers with 4 wires technology.
- Small housing, screw or spring terminals
- Several combination of output contacts
Catalog page
|

|
Safety modules CS AT for emergency stop and gate monitoring with delayed contacts at the opening of the input channels
- Single or dual channel input circuit, 24 VAC/DC; 120 VAC; 230 VAC power supply
- SIL level up to SIL 3 according to EN IEC 62061, Performance Level (PL) up to PL e according to EN ISO 13849-1and safety category up to category 4 according to EN 954-1
- Fixed time or adjustable time versions
- 45 mm housing, screw or spring terminals
Catalog page
|

|
Safety timer module CS FS
- Fixed time or adjustable time versions
- 24 VAC/DC; 120 VAC; 230 VAC power supply
- Small housing, screw or spring terminals
Catalog page
|

|
Safety module CS DM for synchronism control or bimanual control device
- Certificated for bimanual control device type IIIC
- 24 VAC/DC; 120 VAC; 230 VAC power supply
- Small housing, screw or spring terminals
Catalog page
|

|
Standstill monitor safety module CS AM
- Residual voltage at motor-stop selectable on 10 position.
- 24 ... 230 Vac/dc supply voltages
- Possibility to connect single-phase or three phase motors to measuring circuits.
- 45 mm housing, screw or spring terminals
Catalog page
|

|
Expansion module CS ME with istantaneous contacts or delayed contacts at de-energizing
- Usable for the expansion of the safety modules contacts
- Delayed contacts at de-energizing versions (up to 12 sec.)
- Small housing, screw or spring terminals
Catalog page
|